Parker派克电磁阀
Parker Skinner Solenoid Valves
Parker 2-Way Normally Closed, 1-1/2" NPT General Purpose Solenoid Valves
Parker 2-Way Normally Closed, 1-1/2" NPT Solenoid Valves provide operating pressures up to 230 PSI and flow factors up to 29 CV's. They offer brass bodies, multi-mount options and Class F or H or NEMA 4X, 7 or 9 coils for all flow control applications.
Parker's 2-Way Normally Closed 1-1/2" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids and gases. These valves are available in brass construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.
Parker 2-Way Normally Closed, 1-1/2" NPT General Purpose Solenoid Valves
Markets:
- Commercial Equipment
- Food & Beverage
- Industrial Automation
- Oil & Gas
- Process Control
- Transportation
Features/ Benefits:
- High Quality Standards of Skinner? and Gold Ring? Brand
- Modular Design
- Long Life
- Tight Shutoff
Applications:
- Instrumentation Equipment
- Analyzers and Diagnostic Equipment
- Medical and Dental Equipment
- Portable Welding Equipment
- Spraying Equipment
- Lubrication Equipment
- Beverage Dispensing & Vending machines
- Oil Burners
- Humidification and Misting Equipment
- Mobile Fuel Shut Off
- Textile and Dry Cleaning Equipment
- Commercial Dishwashers
- Commercial Laundry and Dryers
- Air Horns
- Pneumatic Fan Clutch
- Irrigation Equipment
Technical Specifications
Product Series: |
7000 and Gold Ring Series |
Valve Type: |
2-Way |
Function: |
Normally Closed |
Port Size: |
1-1/2 inch |
Input Voltage: |
Up to 240/60 (AC) or 24 (VDC) |
Body Material: |
Brass |
Seal Material: |
NBR |
Orifice 1 Size: |
1 to 1-9/16 inch |
Flow Coefficient 1: |
13 to 29 Cv |
Power Consumption: |
6 to 10 (AC) or 10 to 22 (DC) W |
Coil Type: |
1/2" NPT Conduit, 18" Leads, Class F or H, NEMA 7, 9 or 4X, DIN Form A, Class F or H and 1/4 " Tab Terminal, Class F |
Maximum Pressure Differential: |
125 to 230 (AC) or 125 to 230 (DC) psi |
Number of Ports: |
2 |
Actuation Type: |
Manual/Mech. Operated or Offset Diaphragm, Piloted |
Media: |
General Purpose for Air, Liquids and Gases |
Port Type: |
NPT |
Orifice 2 Size: |
n/a |
Flow Coefficient 2: |
n/a |
Minimum Pressure Differential: |
5 psi |
Minimum Fluid Temperature: |
0 °F |
Maximum Fluid Temperature: |
185 °F |
Coil Specifications Met: |
NEMA 4X or NEMA 7, 9, Class F or Class H |
Parker 2-Way Normally Closed, 1-1/2" NPT General Purpose Solenoid Valves型号
Part |
Voltage (V) |
Orifice 1 Size (inch) |
Flow Factor 1 (Cv) |
Power (Watts) |
Coil Type |
Maximum Pressure Differential (psi) |
16F24C2164A3F4C75 |
12 VDC |
1 |
13 |
11.5 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (DC) |
24F24C2180A3F4C75 |
12 VDC |
1-1/4 |
22.5 |
11.5 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (DC) |
24F24C2180A3F4C80 |
24 VDC |
1-1/4 |
22.5 |
11.5 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (DC) |
24F24C2180A3FPH75 |
12 VDC |
1-1/4 |
22.5 |
11.5 Watt (DC) |
DIN Form A, Class F |
125 psi (DC) |
24F24C2180A3FPH80 |
24 VDC |
1-1/4 |
22.5 |
11.5 Watt (DC) |
DIN Form A, Class F |
125 psi (DC) |
24F24C2180AAF4C01 |
24/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
150 psi (AC) |
24F24C2180AAF4C05 |
110/50-120/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
150 psi (AC) |
24F24C2180AAF4C15 |
220/50-240/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
150 psi (AC) |
24F24C2180AAFPH01 |
24/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
DIN Form A, Class F |
150 psi (AC) |
24F24C2180AAFPH05 |
110/50-120/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
DIN Form A, Class F |
150 psi (AC) |
24F24C2180AAFPH15 |
220/50-240/60 |
1-1/4 |
22.5 |
6 Watt (AC) |
DIN Form A, Class F |
150 psi (AC) |
73218BN87N00N0C111C1 |
12 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (DC) |
73218BN87N00N0C111C2 |
24 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (DC) |
73218BN87N00N0C111P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (AC) |
73218BN87N00N0C111Q3 |
220/50-240/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
125 psi (AC) |
73218BN87N00N0C222C1 |
12 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
125 psi (DC) |
73218BN87N00N0C222C2 |
24 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
125 psi (DC) |
73218BN87N00N0C222P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
125 psi (AC) |
73218BN87N00N0C222Q3 |
220/50-240/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
125 psi (AC) |
73218BN87N00N0D100C1 |
12 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
DIN Form A, Class F |
125 psi (DC) |
73218BN87N00N0D100C2 |
24 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
DIN Form A, Class F |
125 psi (DC) |
73218BN87N00N0D100P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
DIN Form A, Class F |
125 psi (AC) |
73218BN87N00N0D100Q3 |
220/50-240/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
DIN Form A, Class F |
125 psi (AC) |
73218BN87N00N0D200C1 |
12 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
DIN Form A, Class H |
125 psi (DC) |
73218BN87N00N0D200P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
DIN Form A, Class H |
125 psi (AC) |
73218BN87N00N0H111C1 |
12 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
125 psi (DC) |
73218BN87N00N0H111C2 |
24 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
125 psi (DC) |
73218BN87N00N0H111P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
125 psi (AC) |
73218BN87N00N0H111Q3 |
220/50-240/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
125 psi (AC) |
73218BN87N00N0H222C2 |
24 VDC |
1-1/4 |
22.5 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
125 psi (DC) |
73218BN87N00N0H222P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
125 psi (AC) |
73218BN87N00N0H222Q3 |
220/50-240/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
125 psi (AC) |
73218BN87N00N0T100P3 |
110/50-120/60 |
1-1/4 |
22.5 |
10 Watt (AC) |
1/4 " Tab Terminal, Class F |
125 psi (AC) |
7321GBN88N00N0C111C1 |
12 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
200 psi (DC) |
7321GBN88N00N0C111C2 |
24 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
200 psi (DC) |
7321GBN88N00N0C111P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
230 psi (AC) |
7321GBN88N00N0C111Q3 |
220/50-240/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X |
230 psi (AC) |
7321GBN88N00N0C222C1 |
12 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
200 psi (DC) |
7321GBN88N00N0C222C2 |
24 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
200 psi (DC) |
7321GBN88N00N0C222P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
230 psi (AC) |
7321GBN88N00N0C222Q3 |
220/50-240/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
230 psi (AC) |
7321GBN88N00N0C322C1 |
12 VDC |
1-9/16 |
29 |
22 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
230 psi (DC) |
7321GBN88N00N0C322C2 |
24 VDC |
1-9/16 |
29 |
22 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X |
230 psi (DC) |
7321GBN88N00N0D100C1 |
12 VDC |
1-9/16 |
29 |
10 Watt (DC) |
DIN Form A, Class F |
200 psi (DC) |
7321GBN88N00N0D100C2 |
24 VDC |
1-9/16 |
29 |
10 Watt (DC) |
DIN Form A, Class F |
200 psi (DC) |
7321GBN88N00N0D100P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
DIN Form A, Class F |
230 psi (AC) |
7321GBN88N00N0D100Q3 |
220/50-240/60 |
1-9/16 |
29 |
10 Watt (AC) |
DIN Form A, Class F |
230 psi (AC) |
7321GBN88N00N0D200C1 |
12 VDC |
1-9/16 |
29 |
10 Watt (DC) |
DIN Form A, Class H |
200 psi (DC) |
7321GBN88N00N0D200P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
DIN Form A, Class H |
230 psi (AC) |
7321GBN88N00N0D300C1 |
12 VDC |
1-9/16 |
29 |
22 Watt (DC) |
DIN Form A, Class H |
230 psi (DC) |
7321GBN88N00N0D300C2 |
24 VDC |
1-9/16 |
29 |
22 Watt (DC) |
DIN Form A, Class H |
230 psi (DC) |
7321GBN88N00N0H111C1 |
12 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
200 psi (DC) |
7321GBN88N00N0H111C2 |
24 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
200 psi (DC) |
7321GBN88N00N0H111P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
230 psi (AC) |
7321GBN88N00N0H111Q3 |
220/50-240/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 |
230 psi (AC) |
7321GBN88N00N0H222C2 |
24 VDC |
1-9/16 |
29 |
10 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
200 psi (DC) |
7321GBN88N00N0H222P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
230 psi (AC) |
7321GBN88N00N0H222Q3 |
220/50-240/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
230 psi (AC) |
7321GBN88N00N0H322C1 |
12 VDC |
1-9/16 |
29 |
22 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
230 psi (DC) |
7321GBN88N00N0H322C2 |
24 VDC |
1-9/16 |
29 |
22 Watt (DC) |
1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 |
230 psi (DC) |
7321GBN88N00N0T100P3 |
110/50-120/60 |
1-9/16 |
29 |
10 Watt (AC) |
1/4 " Tab Terminal, Class F |
230 psi (AC) |
|