Parker 3-Way Normally Open, Pressure in Sleeve-Out Body, 1/4" NPT General Purpose Solenoid Valves

Parker 3-Way Normally Open, Pressure in Sleeve-Out Body, 1/4" Valves provide operating pressures up to 250 psi and flow factors up to 0.28 CV's. They offer a stainless body, multiple mounting positions and coil options for general purpose applications.

 

 

Parker's 3-Way Normally Open, Pressure in Sleeve-Out Body, Direct Acting 1/4" NPT Solenoid Valves are used in a wide variety of applications ideally suited for low to medium pressure applications that do not require a minimum operating pressure differential. Ideally suited for general purpose air, liquids and gases, these valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

 

Parker 3-Way Normally Open, Pressure in Sleeve-Out Body, 1/4" NPT General Purpose Solenoid Valves

 

Markets:
- Commercial Equipment
- Food & Beverage
- Industrial Automation
- Oil & Gas
- Process Control
- Transportation

Features/ Benefits:
- High Quality Standards of Skinner? and Gold Ring? Brand
- Modular Design
- Long Life
- Tight Shutoff

Applications:
- Single acting spring return cylinder control
- Selection or diversion of process media
- HVAC damper control
- Instrumentation Equipment
- Pneumatic positioning
- Automatic dispensing equipment
- Gas sampling
- Small compressors
- Water treatment
- Air dryers
- Analyzers and Diagnostic Equipment
- Medical and Dental Equipment
- Portable Welding Equipment
- Spraying Equipment
- Lubrication Equipment
- Textile and Dry Cleaning Equipment
- Irrigation Equipment

 

Technical Specifications

Product Series: 7000 Series
Valve Type: 3-Way
Function: Normally Open, Pressure in Sleeve-Out Body
Port Size: 1/4 inch
Input Voltage: 110/50-120/60 to 220/50-240/60 (AC) or 12 to 24 (VDC)
Body Material: 430F Stainless
Seal Material: FKM or NBR
Main Orifice Size: 1/16 to 3/64 inch
Main Flow Coefficient: 0.1 or 0.28 Cv
Power Consumption: 10 Watt (AC or DC) W
Coil Type: 1/2" NPT Conduit, 18" Leads, Class F or H, NEMA 4X, 7 or 9, DIN Form A, Class F or H or 1/4 " Tab Terminal, Class F
Maximum Pressure Differential: 125 to 250 psi (AC) or (DC) psi
Additional Options: Exhaust Adapter Nut
Number of Ports: 3
Actuation Type: Direct Acting
Media: General Purpose for Air, Liquids and Gases
Port Type: NPT
Exhaust Orifice Size: 1/16 and 1/32 inch
Exhaust Flow Coefficient: 0.052 to 0.17 Cv
Orifice 2 Size: n/a
Flow Coefficient 2: n/a
Minimum Pressure Differential: 0 psi
Minimum Fluid Temperature: 0 °F
Maximum Fluid Temperature: 185° °F
Coil Specifications Met: NEMA 4X, 7 or 9 or Class F or H

 

Parker 3-Way Normally Open, Pressure in Sleeve-Out Body, 1/4" NPT General Purpose Solenoid Valves型号

Part Voltage (V) Seal Material Orifice Main (inch) Flow Factor Main (Cv) Power (Watts) Coil Type Maximum Pressure Differential (psi)
71395SN2ENJ1N0C111C1 12 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 250 psi (DC)
71395SN2ENJ1N0C111C2 24 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 250 psi (DC)
71395SN2ENJ1N0C111P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 250 psi (AC)
71395SN2ENJ1N0C111Q3 220/50-240/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 250 psi (AC)
71395SN2ENJ1N0C222C1 12 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 250 psi (DC)
71395SN2ENJ1N0C222C2 24 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 250 psi (DC)
71395SN2ENJ1N0C222P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 250 psi (AC)
71395SN2ENJ1N0C222Q3 220/50-240/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 250 psi (AC)
71395SN2ENJ1N0D100C1 12 VDC NBR 3/64 0.1 10 Watt (DC) DIN Form A, Class F 250 psi (DC)
71395SN2ENJ1N0D100C2 24 VDC NBR 3/64 0.1 10 Watt (DC) DIN Form A, Class F 250 psi (DC)
71395SN2ENJ1N0D100P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) DIN Form A, Class F 250 psi (AC)
71395SN2ENJ1N0D100Q3 220/50-240/60 NBR 3/64 0.1 10 Watt (AC) DIN Form A, Class F 250 psi (AC)
71395SN2ENJ1N0D200C1 12 VDC NBR 3/64 0.1 10 Watt (DC) DIN Form A, Class H 250 psi (DC)
71395SN2ENJ1N0D200P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) DIN Form A, Class H 250 psi (AC)
71395SN2ENJ1N0H111C1 12 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 250 psi (DC)
71395SN2ENJ1N0H111C2 24 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 250 psi (DC)
71395SN2ENJ1N0H111P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 250 psi (AC)
71395SN2ENJ1N0H111Q3 220/50-240/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 250 psi (AC)
71395SN2ENJ1N0H222C2 24 VDC NBR 3/64 0.1 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 250 psi (DC)
71395SN2ENJ1N0H222P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 250 psi (AC)
71395SN2ENJ1N0H222Q3 220/50-240/60 NBR 3/64 0.1 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 250 psi (AC)
71395SN2ENJ1N0T100P3 110/50-120/60 NBR 3/64 0.1 10 Watt (AC) 1/4 " Tab Terminal, Class F 250 psi (AC)
71395SN2GNJ1N0C111C1 12 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 150 psi (DC)
71395SN2GNJ1N0C111C2 24 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 150 psi (DC)
71395SN2GNJ1N0C111P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 150 psi (AC)
71395SN2GNJ1N0C111Q3 220/50-240/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 150 psi (AC)
71395SN2GNJ1N0C222C1 12 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 150 psi (DC)
71395SN2GNJ1N0C222C2 24 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 150 psi (DC)
71395SN2GNJ1N0C222P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 150 psi (AC)
71395SN2GNJ1N0C222Q3 220/50-240/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 150 psi (AC)
71395SN2GNJ1N0D100C1 12 VDC NBR 1/16 0.28 10 Watt (DC) DIN Form A, Class F 150 psi (DC)
71395SN2GNJ1N0D100C2 24 VDC NBR 1/16 0.28 10 Watt (DC) DIN Form A, Class F 150 psi (DC)
71395SN2GNJ1N0D100P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) DIN Form A, Class F 150 psi (AC)
71395SN2GNJ1N0D100Q3 220/50-240/60 NBR 1/16 0.28 10 Watt (AC) DIN Form A, Class F 150 psi (AC)
71395SN2GNJ1N0D200C1 12 VDC NBR 1/16 0.28 10 Watt (DC) DIN Form A, Class H 150 psi (DC)
71395SN2GNJ1N0D200P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) DIN Form A, Class H 150 psi (AC)
71395SN2GNJ1N0H111C1 12 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 150 psi (DC)
71395SN2GNJ1N0H111C2 24 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 150 psi (DC)
71395SN2GNJ1N0H111P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 150 psi (AC)
71395SN2GNJ1N0H111Q3 220/50-240/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 150 psi (AC)
71395SN2GNJ1N0H222C2 24 VDC NBR 1/16 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 150 psi (DC)
71395SN2GNJ1N0H222P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 150 psi (AC)
71395SN2GNJ1N0H222Q3 220/50-240/60 NBR 1/16 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 150 psi (AC)
71395SN2GNJ1N0T100P3 110/50-120/60 NBR 1/16 0.28 10 Watt (AC) 1/4 " Tab Terminal, Class F 150 psi (AC)
71395SN2KNJ1N0C111C1 12 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (DC)
71395SN2KNJ1N0C111C2 24 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (DC)
71395SN2KNJ1N0C111P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (AC)
71395SN2KNJ1N0C111Q3 220/50-240/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (AC)
71395SN2KNJ1N0C222C1 12 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (DC)
71395SN2KNJ1N0C222C2 24 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (DC)
71395SN2KNJ1N0C222P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (AC)
71395SN2KNJ1N0C222Q3 220/50-240/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (AC)
71395SN2KNJ1N0D100C1 12 VDC NBR 3/32 0.28 10 Watt (DC) DIN Form A, Class F 125 psi (DC)
71395SN2KNJ1N0D100C2 24 VDC NBR 3/32 0.28 10 Watt (DC) DIN Form A, Class F 125 psi (DC)
71395SN2KNJ1N0D100P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) DIN Form A, Class F 125 psi (AC)
71395SN2KNJ1N0D100Q3 220/50-240/60 NBR 3/32 0.28 10 Watt (AC) DIN Form A, Class F 125 psi (AC)
71395SN2KNJ1N0D200C1 12 VDC NBR 3/32 0.28 10 Watt (DC) DIN Form A, Class H 125 psi (DC)
71395SN2KNJ1N0D200P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) DIN Form A, Class H 125 psi (AC)
71395SN2KNJ1N0H111C1 12 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (DC)
71395SN2KNJ1N0H111C2 24 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (DC)
71395SN2KNJ1N0H111P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (AC)
71395SN2KNJ1N0H111Q3 220/50-240/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (AC)
71395SN2KNJ1N0H222C2 24 VDC NBR 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (DC)
71395SN2KNJ1N0H222P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (AC)
71395SN2KNJ1N0H222Q3 220/50-240/60 NBR 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (AC)
71395SN2KNJ1N0T100P3 110/50-120/60 NBR 3/32 0.28 10 Watt (AC) 1/4 " Tab Terminal, Class F 125 psi (AC)
71395SN2KVJ1N0C111C1 12 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (DC)
71395SN2KVJ1N0C111C2 24 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (DC)
71395SN2KVJ1N0C111P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (AC)
71395SN2KVJ1N0C111Q3 220/50-240/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X 125 psi (AC)
71395SN2KVJ1N0C222C1 12 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (DC)
71395SN2KVJ1N0C222C2 24 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (DC)
71395SN2KVJ1N0C222P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (AC)
71395SN2KVJ1N0C222Q3 220/50-240/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X 125 psi (AC)
71395SN2KVJ1N0D100C1 12 VDC FKM 3/32 0.28 10 Watt (DC) DIN Form A, Class F 125 psi (DC)
71395SN2KVJ1N0D100C2 24 VDC FKM 3/32 0.28 10 Watt (DC) DIN Form A, Class F 125 psi (DC)
71395SN2KVJ1N0D100P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) DIN Form A, Class F 125 psi (AC)
71395SN2KVJ1N0D100Q3 220/50-240/60 FKM 3/32 0.28 10 Watt (AC) DIN Form A, Class F 125 psi (AC)
71395SN2KVJ1N0D200C1 12 VDC FKM 3/32 0.28 10 Watt (DC) DIN Form A, Class H 125 psi (DC)
71395SN2KVJ1N0D200P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) DIN Form A, Class H 125 psi (AC)
71395SN2KVJ1N0H111C1 12 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (DC)
71395SN2KVJ1N0H111C2 24 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (DC)
71395SN2KVJ1N0H111P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (AC)
71395SN2KVJ1N0H111Q3 220/50-240/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 125 psi (AC)
71395SN2KVJ1N0H222C2 24 VDC FKM 3/32 0.28 10 Watt (DC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (DC)
71395SN2KVJ1N0H222P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (AC)
71395SN2KVJ1N0H222Q3 220/50-240/60 FKM 3/32 0.28 10 Watt (AC) 1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9 125 psi (AC)
71395SN2KVJ1N0T100P3 110/50-120/60 FKM 3/32 0.28 10 Watt (AC) 1/4 " Tab Terminal, Class F 125 psi (AC)

 

 

 



信德迈科技(北京)有限公司 - CNMEC Technology
美国DMK Engineering Solutions公司

地址:北京市朝阳区望京街10号望京SOHO-T1-C座2115室
邮编:100102
电话:010-84282935;84283983
手机:13910962635 ( 微信号)
Web: www.increaseinc.cn
Email: sales@cnmec.com
传真:010-84288762


京ICP备08000876号-6

京公网安备 11010502021283
Since 2000 Strong Distribution & Powerful Partnerships